Entrogen REAL-TIME PCR KITS FOR SAMPLE QUALITY ASSESSMENT

ENTROGEN Entrogen REAL-TIME PCR KITS FOR SAMPLE QUALITY ASSESSMENT in India

Entrogen REAL-TIME PCR KITS FOR SAMPLE QUALITY ASSESSMENT
EntroGen’s Sample Quality Assessment kits provide reagents, positive controls, and standards (if applicable) to detect and quantify the amplifiable DNA extracted from patient samples or adaptor-indexed libraries intended for downstream qPCR and NGS assays, respectively.
Read More
Add to Shortlist

Product Details

The accuracy of qPCR and NGS data depends on the quality of the sample. However, DNA extracted from formalin-fixed paraffin-embedded (FFPE) samples may be highly fragmented and contain PCR inhibitors. These factors compromise the sample quality, decrease the quantity of amplifiable DNA, and interfere with PCR amplification. In addition, fragmented DNA reduces the conversion rate of input DNA into adaptor-ligated libraries for downstream sequencing. Traditional methods of quantifying samples using fluorometer-based systems do not detect the presence of PCR inhibitors or measure the amount of amplifiable DNA and properly adaptor-ligated library molecules. Therefore, sample input based on such methods can lead to poor sample representation in qPCR and NGS assays which results in unreliable data, low quality scores in NGS, and patient sample reruns.




Real-time PCR is the most accurate method of quantifying and qualifying both DNA and library inputs for downstream qPCR and NGS assays. Primers designed to bind to reference genes or P5 and P7 adaptor oligos allow for the detection of only amplifiable DNA and properly adaptor-ligated molecules, respectively. Determining sample input by real-time PCR for downstream qPCR and NGS assays will save time, reagents, and patient samples by lowering the probability of inconclusive results and sample reruns.




Available kits for Sample Quality Assessment are as follows :































S.No. Product Name Catalog Number Platform
1 Internal Quality Control Assay IQCA-RT50 For Real Time PCR
2 DNA Fragmentation Quantification Assay FQA-RT40 For Real-Time PCR
3 Library Quantification Kit for Illumina LIBQ-NGS For NGS

EntroGen’s Sample Quality Assessment kits provide reagents, positive controls, and standards (if applicable) to detect and quantify the amplifiable DNA extracted from patient samples or adaptor-indexed libraries intended for downstream qPCR and NGS assays, respectively.



• Internal Quality Control Assay (IQCA): 50 sample tests 



• DNA Fragmentation Quantification Assay (FQA): 40 sample tests 



• Library Quantification Kit for Illumina® (LIBQ): 108 sample tests 



The assessment procedure involves three simple steps:



1) Isolation of DNA from FFPE sections or sequencing libraries.



2) Amplification using the provided reagents in the sample quality assessment kit.



3) Data analysis and interpretation using the real-time PCR software or provided analysis worksheet




EntroGen’s Sample Quality Assessment kits require a real-time PCR instrument capable of detecting FAM and VIC. They do not include reagents for DNA isolation, library preparation, or library clean up.

Read More